DuoMAG TMS Coils

All DuoMAG stimulators are available with an extensive catalogue of coils. Whether your intention is to deliver pairs of pulses to investigate inter-cortical inhibition, or to deliver long trains of rTMS pulses to investigate membrane firing potential, a DuoMAG coil is available for your specific needs.

Request a quote

DuoMAG TMS Coils

DuoMAG TMS Coils

All DuoMAG coils include stimulator controls for triggering and are ergonomically designed for both user and participant comfort. Brainbox are proud to offer coils with such a wide variety of applications including standard coils for thresholding, air and liquid cooled coils for longer protocols, placebo coils for blinded studies and custom solutions for when you can’t find a coil to meet your requirements.

Choosing a DuoMAG TMS coil:

DuoMAG coil names consist of a description of the coil size, shape and sometimes, handle orientation. Typically, coils are referred to as a number denoting the size of the winding, followed by one or two letters, which denote the shape or type of coil (BF being butterfly, and R being round). The letter T always refers to a T shape handle orientation, and finally, the letters LQC refer to the coil being a liquid-cooled coil.

Expand all

Collapse all

DuoMAG 30BFT Coil

DuoMAG 30 BFT CoilFigure of eight butterfly coil with 2x 30mm windings and perpendicular orientation handle. Suitable for very focused cortical stimulation, particularly in animal studies. Anderson connector for compatibility across the DuoMAG range.

DuoMAG 50BF Coil

DuoMAG 50 BF CoilFigure-of-eight butterfly coil with 2 x 50mm windings. Suitable for very focused, cortical stimulation and twin-coil applications, where two coils are used to target two regions in close proximity to each other. Anderson connector for compatibility across the DuoMAG range.

DuoMAG 50BFT Coil

DuoMAG 50 BFT CoilFigure of eight butterfly coil with 2x 50mm windings. Suitable for very focussed cortical stimulation. Perpendicular oriented handles allow two coils to be positioned closer than standard butterfly coils. Applications include twin coil studies where two coils are used to target two regions in close proximity to each other.

DuoMAG 60BF LQC Coil

60BFLQCFigure of 8 coil with two 60mm windings. Suitable for focussed cortical stimulation during heavy dose or repetitive rTMS. Active liquid cooling provides range topping cooling performance during rTMS and paired-pulse protocols.

DuoMAG 70BF Coil

DuoMAG 70 BF CoilFigure of eight butterfly coil with 2 x 70mm windings. Suitable for focused, cortical stimulation. Available with reversed windings for simulating PA/AP comparison studies. Anderson connector for compatibility across the DuoMAG range

DuoMAG 70BF Placebo Coil

70BF PlaceboIdentical to the standard 70mm coil, but internally configured in such a way to deliver only peripheral stimulation but hears the ‘click’ synonymous with TMS, blinding the participant as to whether they are receiving active or sham stimulation. Anderson connector for compatibility across the DuoMAG range.

DuoMAG 70BF Air Cooled Coil

DuoMAG 70 BF Cooled CoilFigure of eight butterfly coil with 2x 70mm windings. Suitable for focused cortical stimulation and repetitive TMS applications. Two fans provide air cooling for prolonged use in rTMS protocols and paired-pulse protocols. Anderson connector for compatibility across the DuoMAG range. Can be used with Deymed counter-balanced electromagnetically controlled coil arm on MagTower or standard coil arm on MagCart.

DuoMAG 70BF Cooled Placebo Coil

70 BF PlaceboIdentical to the air-cooled 70mm coil, but an energy dispersal box mounted on the coil cable limits the amount of current reaching the coil. This in turn means the participant only feels peripheral stimulation on the scalp, but hears the ‘click’ synonymous with TMS, blinding the participant as to whether they are receiving active or sham stimulation.

DuoMAG 70BF Liquid Cooled Coil

DuoMAG 60 BF LQCFigure of eight butterfly coil with 2x 70mm windings. Suitable for focussed cortical stimulation and repetitive TMS applications. Active liquid cooling provides range topping cooling performance during rTMS and paired-pulse protocols. Anderson connector for compatibility across the DuoMAG range. Can be used with Deymed counter-balanced electromagnetically controlled coil arm or standard coil arms.

DuoMAG 70BFX LQC Coil

70 BFX LQCFigure of eight coil with two 70mm overlapping windings. Suitable for focused cortical stimulation designed specifically with the comfort of the participant in mind during heavy dose or repetitive TMS. Active liquid cooling provides range-topping cooling performance.

DuoMAG 90BFVT LQC Coil

90BFVTLQC CoilFigure of 8 V shaped ‘cone coil’ with two 90mm windings on a 120° angled surface and a T shape handle orientation. Suitable for deep stimulation of areas like Cerebellum. Active liquid cooling provides range-topping cooling performance.

DuoMAG 120BFV Coil

120 BFVFigure of eight butterfly coil with 2x 120mm windings in ‘Cone’ orientation. Suitable for deep cortical stimulation. Anderson connector for compatibility across the DuoMAG range

DuoMAG 100R Coil

100 R CoilRound coil with 100mm winding. Suitable for stimulation of peripheral nerves or shallow, non-focused cortical stimulation. Anderson connector for compatibility across the DuoMAG range.

DuoMAG 120BFVT Coil

120 BFVT CoilFigure of 8 V shaped ‘cone coil’ with two 120mm windings on a 100° angled surface and a T shape handle orientation. Suitable for spinal stimulation and deep stimulation areas like Cerebellum.

DuoMAG 125R Coil

120RRound coil with 125mm winding. Suitable for spinal stimulation, peripheral nerve stimulation or non-focussed cortical stimulation. Anderson connector for compatibility across the DuoMAG range.

Compatible Products

This product can be used in combination with some of our other systems. Find out more by selecting one from the list below.

Associated Techniques

To find out more about the techniques that are applicable to this product, follow the links below.

Added Value

In addition to supplying and supporting a wide range of neuroscience products, Brainbox offers additional value in a number of areas that can benefit our customers, including:

Training
Installation, Product Training, Technique Training, Bespoke Training

Lab Support
System Upgrades, Testing, Calibration, System Integration, Bespoke Solutions

Research Support
Study Design, Piloting, Technical Information, References